Low noise |
| |
Extended bandwidth -- DC to 200 Hz |
| |
User-selectable full-scale range |
| |
Calibration coil (standard) |
| |
Single-end or differential output (user selectable) |
| |
Double-stage transient protection |
|
|
|
| Dynamic range: |
155 dB+ |
| Bandwidth: |
DC to 200 Hz |
| Calibration coil: |
Standard |
| Full-scale range: |
User selectable at ± 0.25g, ± 0.5g, ± 1g, ± 2g or ± 4g |
| Outputs: |
User selectable at: ± 2.5V single-ended; ± 10V single-ended;± 5 V differential;± 20 V differential |
| Zero adjust: |
Three user-friendly access holes for simple,safe, efficient adjustment |
| Linearity: |
< 1000 µg/g2 |
| Hysteresis: |
< 0.1% of full scale |
| Cross-axis sensitivity: |
< 1% (including misalignment) |
| Zero point thermal drift: |
< 500µg/°C (1g sensor) |
| ESD, RF, EMI protection: |
Double stage transient protection withgas arrester elements |
| Power consumption: |
12 mA from +/- 12V (Standard Amp), 35 mA from +/- 12 V (Low Noise Amp), Single supply option available |
| Physical size: |
13.3 cm diameter (cylinder), 6.2 cm high |
| Mounting: |
Single bolt mounting, three adjustable leveling feet and bubble level |
| Connection: |
Single military-style metal connector |
| Operating Temperature: |
-20º to 70ºC (0º to 160ºF) |
| Housing: |